Errors related to Mechatronics 8hp  45/50/70/75/90/95   problems:


solenoid output 1

001- No connection selenoid Out1 (open circuit)
112-Resistance deviation too large, Resistance too high
113,114-Resistance deviation too large, Resistance too low
116,117-short to ground
118,128- short to ground solenoid 1 or solenoid 2 (common diagnostics)

solenoid output 2

002- No connection selenoid Out2 (open circuit)
122-Resistance deviation too large, Resistance too high
123,124-Resistance deviation too large, Resistance too low
126,127-short to ground
118,128- short to ground solenoid 1 or solenoid 2 (common diagnostics

solenoid output 3

003- No connection selenoid Out4 (open circuit)
132-Resistance deviation too large, Resistance too high
133,134-Resistance deviation too large, Resistance too low
136,137-short to ground
138,148- short to ground solenoid 3 or solenoid 4 (common diagnostics)

solenoid output 4

004- No connection selenoid Out4 (open circuit)
142-Resistance deviation too large, Resistance too high
143,144-Resistance deviation too large, Resistance too low
146,147-short to ground
138,148- short to ground solenoid 3 or solenoid 4 (common diagnostics)

solenoid output 5

005- No connection selenoid Out5 (open circuit)
152-Resistance deviation too large, Resistance too high
153,154-Resistance deviation too large, Resistance too low
156,157-short to ground
158,168- short to ground solenoid 5 or solenoid 6 (common diagnostics)

solenoid output 6

006- No connection selenoid Out6 (open circuit)
162-Resistance deviation too large, Resistance too high
163,164-Resistance deviation too large, Resistance too low
166,167-short to ground
158,168- short to ground solenoid 5 or solenoid 6 (common diagnostics)

solenoid output 7

007- No connection selenoid Out7 (open circuit)
172-Resistance deviation too large, Resistance too high
173,174-Resistance deviation too large, Resistance too low
176,177-short to ground

solenoid output 8

008- No connection selenoid Out8 (open circuit)
182-Resistance deviation too large, Resistance too high
183,184-Resistance deviation too large, Resistance too low
186,187-short to ground
188,198- short to ground solenoid 8 or solenoid 9 (common diagnostics)

solenoid output 9

009- No connection selenoid Out9 (open circuit)
192-Resistance deviation too large, Resistance too high
193,194-Resistance deviation too large, Resistance too low
196,197-short to ground
188,198- short to ground solenoid 8 or solenoid 9 (common diagnostics)



The above errors indicate problems in mechatronics soldering.


1.errors 1x6, 1x7, 1x8:

The resistance meter should show infinity when we measure the resistance between the case and any pin of the 8hp plug or

should be higher than 1M Ω (R > 1MΩ)


resistance below 1M Ω (R > 1MΩ) may cause errors  1x6, 1x7, 1x8

where x is the selenoid number.


the reason is most often impurities inside the CASE



2. errors 00x :


Problems with a damaged harness, 8hp gearbox pins or TCU plug pins where the problem is with the connection most often cause errors 00x

where x is the selenoid number


You need to check the connections between the 8hp plug and the TCU. Check that the pins connect and that they are plugged into the correct pins of the TCU.


If that didn't solve the problem then you probably have bad PCB/wires soldering in mechatronic. 




3.Selenoid resistance:


Selenoid 1: 5,5Ω

Selenoid 2: 5,5Ω

Selenoid 3: 5,5Ω

Selenoid 4: 5,5Ω

Selenoid 5: 5,5Ω

Selenoid 6: 5,5Ω

Selenoid 7: 5,5Ω

Selenoid 8: 10Ω

Selenoid 9: 25Ω





Helpful photos: