Errors related to Mechatronics problems:


solenoid output 1

001- No connection selenoid Out1 (open circuit)
112-Resistance deviation too large, Resistance too high
113,114-Resistance deviation too large, Resistance too low
116,117-short to ground
118,128- short to ground solenoid 1 or solenoid 2 (common diagnostics)

solenoid output 2

002- No connection selenoid Out2 (open circuit)
122-Resistance deviation too large, Resistance too high
123,124-Resistance deviation too large, Resistance too low
126,127-short to ground
118,128- short to ground solenoid 1 or solenoid 2 (common diagnostics

solenoid output 3

003- No connection selenoid Out4 (open circuit)
132-Resistance deviation too large, Resistance too high
133,134-Resistance deviation too large, Resistance too low
136,137-short to ground
138,148- short to ground solenoid 3 or solenoid 4 (common diagnostics)

solenoid output 4

004- No connection selenoid Out4 (open circuit)
142-Resistance deviation too large, Resistance too high
143,144-Resistance deviation too large, Resistance too low
146,147-short to ground
138,148- short to ground solenoid 3 or solenoid 4 (common diagnostics)

solenoid output 5

005- No connection selenoid Out5 (open circuit)
152-Resistance deviation too large, Resistance too high
153,154-Resistance deviation too large, Resistance too low
156,157-short to ground
158,168- short to ground solenoid 5 or solenoid 6 (common diagnostics)

solenoid output 6

006- No connection selenoid Out6 (open circuit)
162-Resistance deviation too large, Resistance too high
163,164-Resistance deviation too large, Resistance too low
166,167-short to ground
158,168- short to ground solenoid 5 or solenoid 6 (common diagnostics)

solenoid output 7

007- No connection selenoid Out7 (open circuit)
172-Resistance deviation too large, Resistance too high
173,174-Resistance deviation too large, Resistance too low
176,177-short to ground

solenoid output 8

008- No connection selenoid Out8 (open circuit)
182-Resistance deviation too large, Resistance too high
183,184-Resistance deviation too large, Resistance too low
186,187-short to ground
188,198- short to ground solenoid 8 or solenoid 9 (common diagnostics)

solenoid output 9

009- No connection selenoid Out9 (open circuit)
192-Resistance deviation too large, Resistance too high
193,194-Resistance deviation too large, Resistance too low
196,197-short to ground
188,198- short to ground solenoid 8 or solenoid 9 (common diagnostics)



The above errors indicate problems in mechatronics soldering.




Possible solutions:


1. You need to check the connections between the 8hp plug and the TCU. Check that the pins connect and that they are plugged into the correct pins of the TCU.


2. If that didn't solve the problem then you probably have bad PCB/wires soldering in mechatronic. 




Helpful photos:




OLD VERSION: